Trismed will make its position firmly in the world as a practical and future-oriented cardiac diagnosis systems manufacturer by adding new technologies to our accumulated technology, clinical information, and experience. As major leader in Resting ECG, Patient Monitors, Finger Pulse Oximeter, Stress ECG System, Veterinary ECG and Cardipia.

Patient Monitors, Resting ECG, Stress ECG System, Finger Pulse Oximeter Patient Monitors, Resting ECG, Stress ECG System, Finger Pulse OximeterContact UsKorean


Overseas Distributor InformationLocal Distributor InformationCustomer Satisfaction

 Resting ECG - CARDIPIA 800

Resting ECG Cardipia 800

12/6/3-ch recording
216mm roll paper
12/6/1-ch ECG display
High resolution LCD(240x320dots)
Comprehensive interpretation
Full disclosure report(1min)
Snap ECG record(8sec)
PC networking
Stress ECG interface
Real time clock(Date/Time)
Real time heart rate display
Grid record
Arrhythmia detection
Built-in memory(50patients)
Pace maker detection


Technical Specifications / CARDIPIA 800

Recording system High resolution thermal array printer (8 dots/mm)
Recording channel 12/6/3-ch
Recording paper 216mm x 30m thermal sensitive roll paper
Recording ECG Leads 12 standard leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6
Non-interpretation Type 812N
Parameters Type 812P
Interpretation Type 812R
Stress ECG interface Type 812RS
Sensitivity 5, 10, 20mm/mV
Recording speed 5, 10, 12.5, 25, 50mm/sec
Recording operation Automatic / Manual recording
ECG copy Reprint for the last patient
Full disclosure report Captured ECG trace for 1min while displaying ECG
Snap ECG record Latest signal save for 8sec while displaying ECG
ECG acquisition Simultaneous 12-lead ECG acquisition
Alphanumeric data input ID, age, patient name, hospital name and etc with alphanumeric key
Frequency response Filtered 0.5 ~ 30Hz / Unfiltered 0.05 ~150Hz
Digital filter Drift, muscle and AC(50/60 Hz)
1 mV calibration Internal 1 mV signal record for frequency and sensitivity response
A/D Conversion 12bits
Sampling rate 2ms
CMRR Greater than 100dB
Input Impedance Greater than 50Mohm
Performance Comply with AAMI requirements
Safety Class I(Degree of protection against electric shock: Type CF applied parts)
Defibrillator protection 5000VDC
Patient Leakage Current Less than 10
A/C power Free voltage AC 100~240V¡¾10 %, 50/60Hz
D/C power Built-in rechargeable battery (+24V, 600mA, NiCd)
Digital Interface(Option) RS232 to connect external apparatus
Heart rate(Option) 30~200bpm
PC network(Option) ECG data transmission to PC, ECG save on PC, ECG record to PC printer
Real time clock(Option) Date, time(Option)
Arrhythmia detection(Option) Automatic record mode
Pace maker detection(Option) Pace maker detection
Built-in Memory(Option) Up to 50patients
LCD(Standard, 2.5"LCD) Graphic LCD(64 x 128dots), Viewing area: 60 x 32.5mm
LCD(Option, 4"LCD) Graphic LCD(240 x 320dots), Viewing area: 57 x 75mm
LCD(Option, 5.7"LCD) Graphic LCD(240 x 320dots), Viewing area: 90 x 120mm
Auto power off After 5 minutes of complete inactivity
Dimension 333 x 310 x 87mm
Weight 3kg including rechargeable battery
Temperature Operating: 10 ~ 40, Storage: -40 ~ 70
Relative humidity Operating: 30 ~ 75%, Storage: 10 ~ 100%
Atmosphere pressure 700 ~ 1060hPa

812N Non-interpretative ECG recording
812P Major measured cardiac events
Measured parameters of full 12-lead
Averaged 12-lead ECG adn cardiac segments
812R Comprehensive ECG Interpretative
Measured and criteria message
Major measured cardiac events
Measured parameters of full 12-lead
Averaged 12-lead ECG and cardiac segments
812RS Stress ECG interface




Contact UsPatient Monitors, Resting ECG, Stress ECG System, Finger Pulse OximeterOverseas Distributor InformationCustomer Satisfaction