| Anti-electroshock type |
Class I equipment and Internal powered equipment. |
| Size Monitor |
318 X 152 X 264 mm |
| Weight Monitor |
5.5kg |
| Enviroment |
Temperature Working Transport and Storage |
0 ~ 40 -20 ~ 60 |
Humidity Working Transport and Storage |
30 % ~ 85 % 30 % ~ 93 % (no coagulate) |
Altitude Working Transport and Storage |
-500 to 4,600 m -500 to 13,100 m |
| Power Supply |
100/250 VAC, 50/60 Hz, Pmax=80 VA |
| Display |
| Device |
12.1 in Color TFT. 3 LED |
| Messages |
8 Waveforms Maximum 1 Alarm LED (Yellow/Red) 1 Power LED (Green) 1 Battery Charge LED (Green) 3 Sound Mode corresponding Alarm Mode |
| Signal Interface |
| External Display |
Standard VGA |
ECG Output Amplitude Accuracy Impedance Signal Delay |
BNC 1V/mV <5 % 50 <20 mS |
| Battery |
Rechargeable 2.3 A/Hr 12V Lead-Acid battery |
| Recorder (Option) |
48 mm |
| Recall |
Trend Recall Short Long |
1 hrs, 1 Second Resolution. 72 hrs. 1 Min. Resolution. |
| Alarm Event Recall |
60 alarm events of all parameters and 8/16/32 seconds of corresponding waveform |
| NIBP Measurement Recall |
400 NIBP measurement data |
| ECG |
| Lead Mode |
5 Leads(R, L, F, N, C) type(7012S/7010S) |
| Lead selection |
I, II, III, avR, avL, avF, V |
| Waveform |
2 ch |
| Gain |
x2.5mm/mV, x5.mm/mV, x10mm/mV, x20mm/mV auto |
HR and Alarm Range Adult Neo/Ped |
15 ~ 300 bpm 15 ~ 350 bpm |
| Differential Input Impedance |
>5M |
| CMRR |
Monitor >105dB Operation >10dB Diagnosis > 8dB |
| Electrode offset potential |
300mV |
| Leakage Current |
<10 uA |
| Baseline Recovery |
<3s After Defi. |
| ECG Signal Range |
8mV(Vp-p) |
| Bandwidth |
Surgery 1~15 Hz Monitor 0.5~35 Hz Diagnostic 0.05~100 Hz |
| ST Segment Monitoring |
Measure and Alarm -2.0 ~ + 2.0mV |
| Calibration Signal |
1mV(Vp-p), 5% Accuracy |
ARR Detecting Type
Alarm Review |
ASYSOLE, VFIBNTAC, COUPLET, BIGMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Available Available |
| RESPARATION |
| Method |
In |
Differential Input Msauring and Alarm Range Adult Neo/Ped Resolution Accuracy |
0.3 ~ 2.5 Hz 0 ~ 120 rpm 0 ~ 150 rpm 1 rpm
2 rpm |
| Apnea Alarm |
10~40 S |
| NIBP |
| Method |
Oscillometric |
| Mode |
Manual, Auto, STAT |
| Measuring Interval in AUTO Mode |
1,2,3,4,5,10,15,30,60,90,120,180,240,480 Min. |
| Measuring Period in STAT Mode |
5 Min. |
| Pules Rate Range |
40~240 bpm |
| Alarm Type |
SYS, DIA, MEAN |
Measuring and alarm Range Adult Mode Pediatric Mode Neonatal Mode |
10 ~ 270 mmHg 10 ~ 200 mmHg 10 ~ 135 mmHg |
Resolution Pressure |
1 mmHg |
Accuracy Pressure Maximum Mean error Maximum Standard deviation |
5mmHg
8mmHg |
| SpO2 |
| Measuring Range |
0 ~ 100% |
| Alarm Range |
0 ~ 100% |
| Resolution |
1% |
| Accuracy |
70% ~ 100% 2% 0% ~ 69% unspecified |
| Actualization interval |
about 1 Sec. |
| Alarm Delay |
10 Sec. |
Pulse Rate Measuring and Alarm Range Resolution Accuracy Alarm Delay |
0 ~ 254 bpm 1 bpm
2 bpm 10 Sec. |
| MASIMO Specification: |
|
Range Saturation(%SpO2) Pulse Rate(bmp) |
1% ~ 100% 25 ~ 240 |
Accuracy Saturation(%SpO2) Adults
Neonates |
- During No Motion Conditions 70% ~100% 2digits 0% ~ 69% unspecified 70% ~ 100% 2digits |
Saturation(%SpO©ü) Adults
Neonates |
-During Motion Conditions 70% ~ 100% 3digits 0% ~ 69% unspecified 70% ~ 100% 3digits |
| Pulse(bpm) |
-During No Motion Condition 25 to 240 3digits |
| Pulse(bpm) |
-During Motion Condition 25 to 240 5digits |
Resolution Saturation(%SpO2) |
1% |
| Pluse Rate(bpm) |
1 Temperature |
| Channels |
2(7012S, 7010S), 1(7010E) |
| Measuring and Alarm Range |
0 ~ 50 |
| Resolution |
0.1 |
| Accuracy |
0.1 |
| Actualization interval |
about 1 Sec. |
| Average Time Constant |
<10 Sec. |
| IBP |
| Channel |
2 |
| Label |
ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
Measuring and alarm range ART PA CVP/RAP/LAP/ICP P1/P2 |
0 ~300mmHg -6 ~ 120mmHg -10 ~ 40mmHg -10 ~ 300mmHg |
Press Sensor Sensitivity Impedance Resolution Accuracy Actualization interval |
5 uV/V/mmHg 300 ~ 3000 1mmHg
2% or 1mmHg which great about 1 Sec. |
| CO |
| Method |
Thermodilution Technique |
Measuring range CO TB TI |
0.1 ~ 20 L/min 23 ~ 43 0 ~ 27 |
Resolution CO TB, TI |
0.1 L/min 0.1 |
Accuracy CO TB TI |
5% or 0.1L/min, which great
0.1
0.1 |
| Calculation |
CO, Hemodynamic Calculation |
| Alarm Range |
23-43  |
| CO2 |
| Method |
Infra-red Absorption Technique |
| Measuring Mode |
Sidestream or Mainstream (option) |
| Side-stream mode sampling gas flow rate |
100, 150, 200 m/Min (option) |
Measuring range CO2 INSCO2 AwRR |
0 ~ 99 mmHg 0 ~ 99 mmHg 0 ~ 150 rpm |
Resolution CO2 INSCO2 AwRR |
1 mmHg 1 mmHg 1 rpm |
Accuracy CO2
AwRR |
2mmHg, 0 ~ 40 mmHg
5% of reading, 41 ~ 76 mmHg
10% of reading, 77 ~ 99 mmHg
2 rpm |
| Actualization interval |
about 1 Sec. |
| Start-up Time |
<30 sec typical in sidestream mode <80 seconds in mainstream mode from 25¡É ambient, 5W supplied to sensor heater(Mainstream sensor temperature controlled to 42¢ªC) |
| Mainstream Response Time |
100 msec (10% to 90%) |
| Sidestream Rise Time |
240 msec (10% to 90%) |
| Sidestream Delay Time |
1.12 seconds maximum with 7 length 0.055 ID. Sampling line at 175m/min |
Alarm range CO2 InsCO2 AwRR |
0 ~ 99 mmHg 0 ~ 99 mmHg 0 ~ 150 rpm |
| Suffocation Alarm Delay AwRR |
10 ~ 40 Sec. |